The leader in commercial roof edge
and roof ventilation solutions.

Metal-Era Home

Roof Edges

Select Product Type

Narrow Results By:

Product Line



Warranty
Testing






Product Warranty Testing
 

Presto-Tite Fascia

Fully Adhered or Mechanically Attached Single-Ply Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-645 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

Presto-Tite Fascia

Stone Ballast Single-Ply Version  
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-645 approved for wind up lift protection.

Presto-Tite Fascia

Built-Up or Modified Version  
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-645 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

Presto-Tite HG Fascia

Fully Adhered or Mechanically Attached Single-Ply Version  
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

Presto-Tite HG Fascia

Built-Up or Modified Version  
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

Presto-Tite Fascia for Larger Face Heights

Fully Adhered or Mechanically Attached Single-Ply Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-270 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

Presto-Tite Fascia for Larger Face Heights

Built-Up or Modified Version  
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-270 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

Presto-Tite Canted Fascia

Existing Beveled Wood Nailer Version  
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

Presto-Tite Canted Fascia

Galvanized Waterdam Version  
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-270 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

Presto-Tite Canted Fascia for Larger Face Heights

Existing Beveled Wood Nailer Version  
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

Presto-Tite Canted Fascia for Larger Face Heights

Galvanized Waterdam Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-270 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

Presto-Lock Fascia System

Fully Adhered or Mechanically Attached Single-Ply or Built-Up or Modified Version 
  • Factory Mutual 1-90 approved for wind up lift protection.

Johns Manville Drip Edge

 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

Johns Manville Gravel Stop

 

Perma-Tite Coping

Flat Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

Perma-Tite Coping

Tapered Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

Perma-Tite Coping

Existing Slope with Nailer Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.

Presto-Lock Coping

Flat Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.

Presto-Lock Coping

Tapered Version  
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.

Presto-Lock Coping

Over 6" to 12" Face Height, Tapered Version  
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.

Presto-Lock Coping

Existing Slope with Nailer Version  
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.

Presto-Lock Coping

Existing Slope without Nailer Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.