The leader in commercial roof edge
and roof ventilation solutions.

Metal-Era Home

Roof Edges

Select Product Type

Narrow Results By:

Warranty
Testing











Product Warranty Testing
 

GenFlex Fascia

Fully Adhered or Mechanically Attached Single-Ply Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-645 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

GenFlex Fascia

Stone Ballast Single-Ply Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-645 approved for wind up lift protection.

GenFlex HG Fascia

Fully Adhered or Mechanically Attached Single-Ply Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

GenFlex Extended Fascia

Fully Adhered or Mechanically Attached Single-Ply Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-270 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

GenFlex Fascia System 200

Single-Ply Application, Snap-On Version 
  • Face heights of 5 ¼" to 8 ¼" are tested per ANSI/SPRI ES-1 Standard to a design pressure of 160 lbs./ft² and face heights of 9 ¾" to 12 ¾" are tested to a design pressure of 110 lbs./ft² to comply with the International Building Code.

GenFlex Fascia System 200

Single-Ply Application, Crimp-On Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 150 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-195 approved for wind up lift protection.

GF One Edge

Fully Adhered or Mechanically Attached Single-Ply Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 200 lbs./ft² to comply with the International Building Code.

GenFlex Econo Drip Edge

 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

GenFlex Econo Gravel Stop

 

GenFlex Coping

Flat Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

GenFlex Coping

Tapered Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

GenFlex Coping

Over 6'' to 12'' Face Height, Tapered Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual approved for wind up lift protection.

GenFlex Coping

Larger than 16'' Wall Size Tapered Version  
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

GenFlex Double Tapered Coping

 

Arched Coping

 

GenFlex Econo Coping

Flat or Tapered Version