Fully Adhered or Mechanically Attached RubberGard or UltraPly Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to a design pressure of 170 lbs./ft² to comply with the International Building Code.
- Factory Mutual 1-750 approved for wind up lift protection.
- Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Stone Ballasted RubberGard or UltraPly Version
|
|
-
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft² to comply with the International Building Code.
-
Factory Mutual 1-645 approved for wind up lift protection.
|
|
Built-Up or Modified Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft² to comply with the International Building Code.
- Factory Mutual 1-645 approved for wind up lift protection.
- Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Platinum Version
|
|
-
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft² to comply with the International Building Code.
-
Factory Mutual 1-645 approved for wind up lift protection.
-
Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Fully Adhered or Mechanically Attached RubberGard or UltraPly Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
|
|
Built-Up or Modified Version
|
|
-
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
|
|
Platinum Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
|
|
Fully Adhered or Mechancially Attached RubberGard or UltraPly Version
|
|
-
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
-
Factory Mutual 1-270 approved for wind up lift protection.
-
Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Built-Up or Modified Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
- Factory Mutual 1-270 approved for wind up lift protection.
- Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Platinum Version
|
|
-
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
-
Factory Mutual 1-270 approved for wind up lift protection.
-
Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Existing Beveled Wood Nailer Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
- Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Galvanized Waterdam Version
|
|
-
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
-
Factory Mutual 1-270 approved for wind up lift protection.
-
Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Existing Beveled Wood Nailer Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
- Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Galvanized Waterdam Version
|
|
-
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
-
Factory Mutual 1-270 approved for wind up lift protection.
-
Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Fully Adhered, Mechanically Attached or Stone Ballast RubberGard or UltraPly Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
- Factory Mutual 1-90 approved for wind up lift protection.
|
|
Single-Ply Application, Snap-On Version
|
|
-
Face heights of 5 ¼" to 8 ¼" are tested per ANSI/SPRI ES-1 Standard to a design pressure of 160 lbs./ft² and face heights of 9 ¾" to 12 ¾" are tested to a design pressure of 110 lbs./ft² to comply with the International Building Code.
|
|
Single-Ply Application, Crimp-On Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to a design pressure of 150 lbs./ft² to comply with the International Building Code.
- Factory Mutual 1-195 approved for wind up lift protection.
|
|
|
|
-
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
|
|
|
|
|
|
Flat Version
|
|
-
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
-
Factory Mutual 1-90 approved for wind up lift protection.
-
Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Tapered Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
- Factory Mutual 1-90 approved for wind up lift protection.
- Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.
|
|
Over 6'' to 12'' Face Height, Flat Version
|
|
-
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
-
Factory Mutual approved for wind up lift protection.
|
|
Over 6'' to 12'' Face Height, Tapered Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
- Factory Mutual approved for wind up lift protection.
|
|
Larger than 16'' Wall Size Tapered Coping
|
|
-
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
|
|
Existing Slope with Nailer Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
- Factory Mutual 1-90 approved for wind up lift protection.
|
|
Existing Slope without Nailer Version
|
|
-
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
-
Factory Mutual 1-90 approved for wind up lift protection.
|
|
Existing Slope without Nailer, Over 6'' to 12'' Face Height, Masonry Attached Version
|
|
- Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
|
|
|
|
|
|
|
|
|
|
|
|
-
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 340 lbs./ft² to comply with the International Building Code.
|
|
|
|
|
|
|
|
|