The leader in commercial roof edge
and roof ventilation solutions.

Metal-Era Home

Roof Edges

Select Product Type

Narrow Results By:

Warranty
Testing











Product Warranty Testing
 

SecurEdge 2000 Standard Fascia

Fully Adhered or Mechanically Attached Single-Ply Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-645 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

SecurEdge 2000 Standard Fascia

Stone Ballast Single-Ply Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-645 approved for wind up lift protection.

SecurEdge 2000 HG Fascia

Fully Adhered or Mechanically Attached Single-Ply Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

SecurEdge 2000 Standard Fascia for Larger Face Heights

Fully Adhered or Mechanically Attached Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-270 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

SecurEdge 2000 Canted Fascia

Existing Beveled Wood Nailer Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

SecurEdge 2000 Canted Fascia

Galvanized Waterdam Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-270 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

SecurEdge 2000 Canted Fascia for Larger Face Heights

Existing Beveled Wood Nailer Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

SecurEdge 2000 Canted Fascia for Larger Face Heights

Galvanized Waterdam Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-270 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

SecurEdge 1000 Fascia System

Fully Adhered or Mechanically Attached Single-Ply Version 
  • Factory Mutual 1-405 approved for wind up lift protection.

SecurEdge 1000 Fascia System

Stone Ballast Single-Ply Version 
  • Factory Mutual 1-405 approved for wind up lift protection.

SecurEdge 200 Fascia System

Single-Ply Application, Snap-On Version 
  • Face heights of 5 ¼" to 8 ¼" are tested per ANSI/SPRI ES-1 Standard to a design pressure of 160 lbs./ft² and face heights of 9 ¾" to 12 ¾" are tested to a design pressure of 110 lbs./ft² to comply with the International Building Code.

SecurEdge 200 Fascia System

Single-Ply Application, Crimp-On Version 
  • Tested per ANSI/SPRI ES-1 Standard to a design pressure of 150 lbs./ft² to comply with the International Building Code.
  • Factory Mutual 1-195 approved for wind up lift protection.

Sure-Seal® 200 Drip Edge

 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

SecurEdge 200 1 Pc. Gravel Stop

 

Carlisle Anchor-Tite Coping

 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.

SecurEdge 200 Coping

Flat Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

SecurEdge 200 Coping

Tapered Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.
  • Miami-Dade Approved (No. 08-0604.02 12/11/13) to comply with the “High Velocity Hurricane Zone of the Florida Building Code”.

SecurEdge 200 Coping for Over 6'' to 12'' Face Heights

Flat Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual approved for wind up lift protection.

SecurEdge 200 Coping for Over 6'' to 12'' Face Heights

Tapered Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual approved for wind up lift protection.

SecurEdge 200 Coping for Over 6'' to 12'' Face Heights with Masonry Attachment

Tapered Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

SecurEdge 200 Coping for Larger than 16'' Wall Size

Tapered Version 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

SecurEdge 200 Coping for Use with Existing Slope with Nailer

 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.

SecurEdge 200 Coping for Use with Existing Slope without Nailer

 
  • Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
  • Factory Mutual 1-90 approved for wind up lift protection.

Carlisle Double Tapered Coping